Part Number:
ETI0001-1453
NSN: 6130-01-539-9645
Rugged Mil Spec® 4000 VA Integrated
Rackmount UPS and Intelligent
Power Distribution Unit Combination
w/ Dual Source Input
ETI0001-1453 Dual Source Input Military Power®
NSWC StandardConfiguration for MK 119 MOD 0 Gun Computing System
Isolated Mil Spec UPS, 4000 VA Rugged Rack Mount UPSw/ PFC and
Integrated 6 Circuit, 2 Pole, Intelligent, Solidstate Power Distribution Unit
P/N:
ETI0001-1453 Rugged Mil Spec UPS and PDUStandard Front
Panel Layout w/ 2U Battery Module
NSN: 6130-01-539-9645
P/N:
ETI0001-1453 Rugged Mil Spec UPS and PDU Standard Rear
Panel Layout w/ 2U Battery Module
The field proven Military Power® UPS line is ideally suited for military,industrial, computer and telecommunications applications requiring high reliability, rugged construction, compact size and light weight design.These units are equally suited for use in shipboard, airborne, vehicular, fielddeployed or fixed locations with controlled or uncontrolled environments. The
ETI0001-1453 was specifically designed for US Navy MK 119 MOD 0 Gun Computing Systemsrequiring higher power requirements.The
ETI0001-1453 does not require a separate PDU since the PDUfunctions are already integrated into the UPS module. This saves rack space,cabling and expense while improving overall reliability.
The 3Uelectronics module can be mounted in the upper section of the rack near eyelevel or lower in the rack near the battery module. The heavier 2U batterymodule is usually mounted in the bottom of the rack for lowering the center ofgravity of the rack. A heavy duty shielded cable is provided to connectthe two modules. Both chassis have roundedmetal corners and rugged handles, both front and rear, aiding in safe handling. Internally, all major components are well secured and electrically insulated to preventdamage due to shock and vibration in any axis. These units can be mountedhorizontally or vertically.
The internal shieldedinput transformer provides galvanic isolation with provisions for domestic (115 VAC, CONUS) and optionally for international (230 VAC, OCONUS) inputvoltages. Theunit also operates as a frequency converter, taking 46-70 hertz input andconverting it to 60 hertz power. Special EMI/RFI filters and inputpower factor correction minimize both input current and harmonics. The inputcircuit breaker and the galvanic isolation transformerall provide a double pole isolated source for all installations including shipboard systems oroverseas locations where phase references and grounding are not consistent. Toprovide added flexibility and reliability, the “
ETI0001-1453” accepts two independentAC power sources. The UPS can operate from either power source automatically anddoes not use its battery unless both sources have failed.
The LED arrays keep the operator informed as tothe unit's status including load and battery levels. The high intensity audible alarm canbe heard in high noise environments.All controls and protective devices are brought to front and rear panels with criticalswitches having finger guards. Further, all front panel devices are recessed to preventdamage or accidental operation. The internal intelligent PDU allows control ofthe individual output circuits incorporating thermal and interlock interfacesfor additional control and safety, plus Battleshort override. The display andcontrol panel can be mounted remotely in the rack at eye level, or on the keyboard console,or on the unit front panel with only a logic level cable connection.
The rear panel provides lockingconnectors for the input and output power with various optional configurationsavailable. The output connectors are MS threaded metal shell connectors. Thisunit draws air through the rear and exhausts out the side vents into the rack.This allows the unit to be used in either positive, negative or neutral pressureracks. A removable and washable intake air filter and high capacitystainless steel ballbearing fans provide added protection in both controlled and hostile environments. The external battery connector allows the safe and easy addition ofthe standard or extra battery modules without having to shut the unit down.The batteries are maintenance free with immobilized electrolyte and areconstructed of flame retardant materials. For more information, see the BatteryTechnology section. Afrequency selection switch is available for those sites requiring 50 hertz output insteadof the standard 60 hertz. The Status connector provides aninterface with optional computer software providing loss of AC and low battery status as well asremote shut down capability. The PDU Remote Control connector provides aninterface to optional remote display/control panels.
See the Power Distribution Units section for a listing ofstand alone PDUs. See the N3 Series UPS section for UPS withoutthe integrated PDU and remote control.
Overall, the Rugged Power line is uniquely qualified for critical shipboard, vehicle,airborne or land based systems combining advanced modular design features with highlyreliable construction
AC OUTPUT | |
Output voltage: | 120 VAC true sinewave standard, others optional |
Output rating: UPS | 4000 VA standard in 3U electronics chassis 0.65 to 0.75 pf standard, optional configurations to 24,000 VA |
Non-linear load capacity: | Up to 100% non-linear load capability w/o derating |
Output voltage regulation: UPS | ± 3.0% static regulation of nominal ± 4.0% dynamic (0 to 50% load step) |
Overload surge capacity: | 110% for 10 minutes; 125% for 30 seconds |
Harmonic distortion: | Less than 5.0% into 100% non-linear load |
Output frequency: UPS | 60 or 50 Hz ± 2.5% synchronized to utility 60 or 50 Hz ± 1.0% w/ utility not available 400 or 1000 Hz output available as an option |
Operational status | Status, load and battery level LEDs, w/contacts Adjustable level,+90 dB audible alarm w/on/off |
AC INPUT | |
Input voltage selection: | Dual Source Input, two separate AC sources, J1A and J1B Nominal 115 VAC, optional autoranging input of 85-270 VAC |
Input voltage tolerance: UPS | 85-135 VAC @ full load without using battery, to 70 VAC @ 75% load |
Input frequency: | From 46 Hz to 70 Hz standard, optional to 440 Hz |
Input power factor: | Better than 99% typically |
Input/output isolation: | 4000 VA, up to 120 dB common mode, <1.0 mA leakage |
Input transient suppression: | Complies with IEEE 587 and UL 1449 |
Input control/protection: | Guarded 2 pole input breaker w/ UPS fuses Optional cold start to turn on w/o AC present |
Input power connection: | (2) MS3102-22-2P threaded locking |
EXTERNAL BATTERY | |
Battery type: | Maintenance free immobilized electrolyte, Flame retardant materials, Oxygen Index 28+ |
Battery life: | Rated for continuous service life of 5 years |
DC protection: | Panel mounted fuses standard, breaker optional |
Battery expansion: | Up to 24 hours w/ Battery Expansion Modules |
DISTRIBUTION PANEL | |
Output circuits: | Six controlled outputs via solidstate relays |
Output control: | Local/remote control panel w/rocker switches Thermal and remote interlock ON/OFF control |
Output receptacles: | MS3470W14-4S threaded locking, various options |
MECHANICAL | |
Dimensions ( H x D x W ): UPS 2U Battery Module |
5.25 (3U) x 23.5 x 19.0 in (133 x 597 x 483 mm) 3.50 (2U) x 23.5 x 19.0 in (89 x 597 x 483 mm) |
Rack Slide Mount Patterns: | Jonathan, General Devices patterns standard, others optional |
Alternate Mounting Options: | Table, Wall, Floor, Portable, Horizontal/Vertical |
Shipping weight: UPS 2U Battery Module |
95 lb. ( 43 kg) with lift handles front and rear 102 lb. ( 72 kg) with lift handles front and rear |
Audible noise: | Less than 47 dB @ 5.0 ft., ANSI "A" scale |
Cooling type: | High capacity, negative pressure, forced air |
Cooling air direction: | Rear intake, exhaust to sides, others optional |
Air intake filter: | Washable metal filter media, others optional |
ENVIRONMENTAL | |
Storage temperature: | -40° to 158° F ambient (-40° to 70° C) with fully charged batteries |
Operating temperature: | 32° to 113° F ambient (0° to 45° C ), lower/ higher optional |
Operating humidity: | 0 to 95% relative humidity (non-condensing) |
Storage elevation: | Up to 40,000 ft (12,192 m) |
Operating elevation: | Up to 15,000 ft (4,572 m), higher optional |
STANDARDS | |
United States: | Meets UL-1778 standard for UPS equipment, MIL STDs 167-1, 454, 810, 901D Grade A, 1399-300A & 2000 |
Canada: | CSA C22.2 No. 107 UPS safety requirements |
EMI Protection: | EMI/RFI FCC Part 15, Class A; EN55022; MIL STD 461 |
OPTIONAL ACCESSORIES | |
Autoranging International Input, Cold Start, Alternate I/O Configurations, Battery Expansion, Batteryless Operation, Battery Charger/Conditioner, Power Distribution Units, Software Interface, Asynchronous serial COM port, 10BaseT Ethernet SNMP/HTTP port, Transport Cases, Slides and Mounting Kits |