LinkedIn



P/N: ETI0001-1151 Rugged Rackmount Universal Intelligent Battery Charger / Conditioner, NSN: 6130-01-458-1088

Part Number: ETI0001-1151
Supersedes: ETI0001-1150
NSN: 6130-01-458-1088
Multiple Output Intelligent 
Battery Charger and Battery Conditioner


Universal Rugged Power UPSBattery Charger / Battery Conditioner
48 VDC, 72 VDC and 78 VDCOutput
85-270 VAC, 46-70 Hz Input

P/N: ETI0001-1151 Front Panel Layout with Rack Mount Flanges NSN: 6130-01-458-1088
P/N:
ETI0001-1151 Front PanelLayout with Rack Mount Flanges
NSN: 6130-01-458-1088

P/N: ETI0001-1151 Rear Panel Layout with Rack Mount Flanges
P/N:
ETI0001-1151 Rear PanelLayout with Rack Mount Flanges

ETI uses the highest quality, maintenance-free, immobilizedelectrolyte, lead-acid batteries in all of its Rugged Power™,WorldPower™and Military Power® UPS products. However as with all lead-acid batteries, there is an internalself discharge that will over time discharge the battery when not beingcharged. Three basic factors effect the shelf life of batteries: the chargestate when stored, the storage temperature, and the length of time storedwithout being recharged. A battery should never be stored in a dischargedstate, otherwise it will form lead sulfate that permanently damages thebattery. If a battery is stored fully charged at 68°F (20°C), then it would require arecharge at least once every six months to maintain its design life. If thestorage temperature is 88°F (40°C), the storage time between supplementary charges is less thanthree months. With some projects stretching out over many months, maintainingthe charge state of the batteries in the UPS can be a problem. Secondly,attempting to stock spare battery packs or modules for deployed units becomesan even more difficult task since they do not have their own charger like theUPS.

Designed for either in a rack or on a bench top, the ETI0001-1151 Charger/Conditioner isideally suited for periodic or continuous maintenance of the batteries in theUPS as well as spare Battery Modules. The ETI0001-1151 is specifically designed to support ETI UPS products from 1.0 kVAthrough 6.0 kVA, including the JMCIS, DTC-2, TAC-3 and TAC-4 UPS. Theheavy-duty chassis, occupying only 3.5” of rack space, has rounded metalcorners and rugged handles, aid in safe handling. Internally, all majorcomponents are well secured and electrically insulated to prevent damage due toshock and vibration. The front panel meters and LEDs keep the operator informedas to the unit's status including charge voltage, current, and charge state.All controls and protective devices are brought to front panel and are recessedto prevent damage or accidental operation. The rear panel provides lockingconnectors for the input and output power. The four output connectors useadapter cables to interface directly with the UPS units and/or with the sparebattery modules. An output selector switch allows the operator to choosebetween the three nominal outputs. Output current is specifically regulated foroptimal battery life, including compensating for ambient temperatures. 

In addition to maintaining the correct charge on the battery, the ETI0001-1151 has a Battery Conditioner Section. Battery Conditioning isinitiated by pressing a switch on the front panel. This starts a programmedcycle beginning with the first battery connected. It performs a gradualdischarge of the battery to a specific level, then begins recharging thebattery. This discharge/recharge cycle serves to freshen the battery so that itcan perform better on demand. Once it has completed this cycle on the firstbattery connected, it starts the same cycle with each subsequent batteryconnected.

The internal input transformer provides galvanic isolation with provisions for both domestic (115 VAC, CONUS) and international (230 VAC, OCONUS) input voltages. The autoranging input voltage selection allows inputting either 115 VAC or 230 VAC without having to open the enclosure. The input switch and the galvanic isolation transformer provide a double pole isolated source for all installations including shipboard systems or overseas locations where phase references and grounding are not consistent.

Overall,the ETI0001-1151 provides a reliable yet simple solution to the issue of maintainingUPS batteries while in storage.

Technical Specifications:
P/N: ETI0001-1151
NSN: 6130-01-458-1088

DC OUTPUT

Output voltage

48, 72 or 78 VDC nominal switch selectable

Output rating:

2 amps max, current limited

Non-linear load capacity:

Up to 100% non-linear load capability

Output voltage regulation:

intelligent voltage regulation for optimum battery charge rate

Overload surge capacity:

110% for 10 minutes; 125% for 30 seconds

Operational status:

Output voltmeter
Output ammeter
Status LEDs

AC INPUT

Input voltage selection:

Autoranging from nominal 115 VAC to 230 VAC
+15% -25%, or 85-135 and 170-270

Input frequency:

From 46 to 440 Hz

Input/output isolation:

2000 VA,
120 dB common mode,<5mA leakage

Input transient suppression:

Complies with ANSI C62.41 1980, IEEE 587

Input control/protection:

Guarded 2 pole switch (S1) w/fuse (F2)

Input power connection:

MS 3102A-22-2P, 3 pin, locking,

DISTRIBUTION PANEL 

Output circuits:

Four outputs standard

Output receptacle:

AMP CPC, 3 pin locking

MECHANICAL

Dimensions   ( H x D x W ):

3.50 (2U) x 15.0 x 19.0 in  (89x381x483mm)

Rack slide mount patterns:

General Devices slide pattern

Alternate Mounting Options:

Table, Wall, Floor, Portable, Horizontal/Vertical

Unit weight:

20 lb. (9 kg) with lift handles front and rear

Audible noise:

Less than 47 dB @ 5.0 ft., ANSI "A" scale

Cooling type:

Internal circulation forced air

ENVIRONMENTAL

Storage temperature:

-13° to 140° F ambient  (-25° to 60° C)

Operating temperature:

 32° to 104° F ambient  ( 0° to 40° C)

Operating humidity:

0 to 95% relative humidity (non-condensing)

Storage elevation:

Up to 40,000 ft (12,192 m)

Operating elevation:

Up to 15,000 ft (4,572 m), higher optionally

STANDARDS

United States:

Meets UL-1778 standard for UPS equipment,
MIL STDs 810, 454 & 1399 Shock/Vib/Electrical

Canada:

CSA C22.2 No. 107 UPS safety requirements

EMI Protection:

EMI/RFI FCC, Class A

Request Product Information
*(denotes required field)
Contact ETI by mail at:
Energy Technologies, Inc.
219 Park Avenue East
Mansfield, OH 44902-1845
USA

Contact ETI by phone or fax:
Voice: 419-522-4444
FAX: 419-522-4466